what breakers are compatible with ge

When installing a circuit breaker on a GE panel, you must know its rated current because it will be compatible with that system if the rated current matches with the GE panel. If you have queries, check the GE website. The homeline breakers are known to fit in the siemens panel, I know CH are capable with many different brands, not sure about GE. Square D Homeline Compatible Breakers. Is a GE THQL 2115 15A 2 P Breaker Interchangeable with a Cutler Hammer BRD&A 15 amp double breaker? I just discovered the electrician who added c. 20 breakers (new circuits) to my GE panel used SqD HOM breakers last year. We need to rely on some parameters to use another breaker instead of one that fits your ge panel. Share Improve this answer Follow answered Jan 19, 2022 at 20:41 Siemens and Eaton both have Classified breakers that go into QO panels. These are two entirely different type of circuit breaker. You can interchange them and use them securely. Manufacturers print the wattage Can You Leave Doorbell Wires Exposed? GE panels can work with other brands. These breakers are UL-listed and UL-classified. While Siemens breakers can be used in GE breaker boxes, not all GE breakers will function properly. Standard Step Height and Depth (Complete Guide), Standard Toilet Flange Height (Complete Guide). The BR-series from Eaton is your best bet for replacing a Bryant breaker., Aside from the BR-series from Eaton, there are very few options available to replace a Bryant breaker. And by keeping the desired voltage unchanged, we can easily use another breaker instead of a circuit breaker of the same feature on that ge panel. Some breaker companies went under because their breakers are dangerous; Federal Pacific, for instance. WebThe Siemens circuit breakers are compatible with the ge panels. GE understands its technology better than anyone. In both cases, there is a need to maintain the consistency of the frequency. (Explained), That hasnt stopped people from using square D breakers in GE panels. Square D Can You Use Cement Board Behind a Wood Stove? After all, GE is interchangeable with brands like Siemens that work with Eaton breakers and panels. However, the UL Classified breaker cannot be used in GE panels. They are rated with different compatibility. So, who do you think is the best manufacturer for the job? Is a GE THQL 2115 15A 2 P Breaker Interchangeable with a Cutler Hammer BRD&A 15 amp double breaker? Are Siemens and Square D breakers compatible? GE breakers will work in Cutler-Hammer panels, but you will need to use an adapter because they don't fit. Eaton Breakers with Cutler-Hammer. However, Square D added a small protrusion on their bus bars to reject those other breakers from being installed in 2). Compatibility may also come from third-party breakers, but they are not safe. Send them pictures of the panel, and they will show you the breaker that can work with it. Which breakers are interchangeable? Finally, Cutler-Hammer is another brand that you can interchange with Murray. Yes, GE Circuit Breakers can be returned and have a 90-Day return period. You will also find some other breakers compatible with the ge panels. PortablePowerGuides is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. The Breaker Must Share the Same Operational Features Can GE Circuit Breakers be returned? It would be helpful to know what breakers are compatible with GE panel. Some breakers, such as bolt-in breakers, are not interchangeable with others; there are many different types of breakers to choose from. The Breaker Must Share the Same Operational Features The Eaton breakers and GE panels both fit, which means the Eaton breakers are compatible with the GE panels. WebAs a result, Westinghouse circuit breakers work with Cutler-Hammer, Eaton, and Square D breakers. Dont assume that a breaker will fit any random panel if it is the same manufacturer. WebAs a result, Westinghouse circuit breakers work with Cutler-Hammer, Eaton, and Square D breakers. #1. Aug 9, 2017. This is because square D does not make classified breakers. Well, , Conduits may provide protection for a 6/3 cable, and they can be used to bundle up multiple wires. Its one of the markets most readily accessible and reliable circuit breaker brands, so electricians often prefer it to other brands. Some brands have bought out other brands, which means their breakers are compatible. Some companies will tell you that their panels will only accept breakers from their brand. Because of the similarities between different brands breakers, you can swap them out without fear of introducing an arc fault into your electrical system. Some of the circuit breakers available in the market match the GE panel smoothly. Get Free estimates from licensed electricians in your area today. What you were sold is a GE 2 pole breaker. 4 Easy Steps. It appears to me that what you wanted was a Cutler-Hammer tandem breaker (Type BRD). The Bryant breakers are not compatible with the GE panels. You usually have a list of a dozen or more breakers that fit the panel. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. I know CH are capable with many different brands, not sure about GE. However, there are still a number of breaker-compatible brands that have high Bryant breaker compatibility. Always replace a damaged Westinghouse breaker with a new unit from the same manufacturer. One of those companies was Eaton/Cutler-Hammer. The homeline breakers are known to fit in the siemens panel, WebMurray circuit breakers are compatible with a wide range of breakers on the market. ccurrins (Christopher Currins, CMI) September 25, 2015, 1:49am #1. The most secure method is to utilize GE circuit breakers with GE breaker boxes. Replacing a panel box is expensive work, so you should locate an acceptable replacement for the breaker if possible unless the box presents a safety hazard., Weve all heard of General Electric and likely have at least one appliance or electrical device made by the company. Their breakers have unique mounting mechanisms that are only compatible with panels from the same brand. For instance, Siemens 1 and 2 wide breakers are not compatible with Square D panels. WebGE Q-Line THQP 15-Amp 1-Pole Standard Trip Circuit Breaker Model # THQP115 Find My Store for pricing and availability 138 GE Q-Line THQL 125-Amp 2-Pole Standard Trip Circuit Breaker Model # THQL21125P Find My Store for pricing and availability 357 GE Q-Line THQP 30-Amp 2-Pole Standard Trip Circuit Breaker Model # THQP230 Find My Store Manufacturers usually provide a list of brands in whose panels their breakers can work. However, some discourage the use of Eaton breakers in GE panels because GE panels are not included in the list of brands with whom Eaton breakers can work. We have an affiliate partnership with Networx, Reasons You Might Need to Use a Different Breaker, What to Look for When Interchanging Breakers. But some may come with a different rating and create some compatibility reasons. But that is because they dont want you to buy a competitors breakers. Touching these conductors can Hi, my name is Stellar and I'm an Electrical Engineer. Are all ge circuit breakers interchangeable? The UL or Underwriters Laboratory goes to great lengths to test different breakers with different panel boxes., They wont give their certification to a breaker unless they have proven firsthand that you can use it safely in other panel boxes. Consider the classifications recommended by the panel manufacturer. The Breaker Must Be Similar To The Original Design. What breaker will interchange with Cutler-Hammer? Guide to Finding Breakers Compatible with Square D. 1). (Explained). But from Google's view of their pages, it's clear they don't make UL-classified breakers for GE panels. WebThe Siemens circuit breakers are compatible with the ge panels. I know Seimens makes one for Sq.D, etc Jraef Moderator Staff member Location San Francisco Bay Area, CA, USA Occupation Electrical Engineer Aug 22, 2012 #3 You cannot approach it from the GE panel side, their answer will always be the same: GE. You can use it on the GE panels if they match a certain Square D breaker. So, you need to check everything before installing on your GE panels. In the case of using a breaker in an electrical connection, it is necessary to determine the adequate frequency in that line and place it accordingly. What Gauge Extension Cord for a Space Heater? Breakers from different brands have unique designs that can cause malfunctions if you fit them in the wrong panel. Square D However, Siemens QD Series breakers are compatible with Square D load centers. The first options you should look for are Siemens QAF, QPF, QT, and QP. However, like all electrical parts, circuit breakers tend to go bad and must be replaced. Also, you can call a professional electrician and ask which brand and type of breaker is interchangeable with your GE unit. Contact Eaton for clarity if youre tempted to use a GE breaker in their panel. Siemens, of course, is the most well-known brand. Consider the classifications recommended by the panel manufacturer. They will also specify which panel boxes and breaker brands are interchangeable., Murray was bought out by Siemens. Normally THQL is cheaper, but it's rather useful for early GE panels that THQL breakers are not compatible with. As a result, finding a Challenger circuit breaker is extremely challenging. They make the QD type for Square D "QO" panels, and the MSQ type also for Square D "QO" panels. The answer is also yes. Some manufacturers wont give you a choice in the matter. However, you cannot use all the circuit breakers with the ge panels; there are some power differences between them. Purchasing the wrong breaker can result in a malfunction or even a burnt out breaker. They also get sold by most electrical companies and wholesale electrical outlets. What Size Conduit for 6/3 Wire? Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. GE circuit breaker cross reference for obsolete and other brand units is possible. I just discovered the electrician who added c. 20 breakers (new circuits) to my GE panel used SqD HOM breakers last year. GE has breakers that can work in panels from other brands. WebWhat breakers are compatible with GE THQL breakers? What Breakers are Compatible with Siemens? You can also use Eaton with Murray breakers because Cutler-Hammer and Eaton breakers are the same.Breaker BrandInterchangeable With MurrayInterchangeable with Murray but with restrictionsSiemensYes, from 2002 onSquare DYesCutler-Hammer and EatonYes, but check local codeAir Circuit BreakerYes, only up to 450 volts, As weve just discussed, Siemens bought out Murray and made it so that all their circuit breakers were compatible from the year 2002 onward. Did you find this article helpful? Floating Shelf Height: How High Should a Floating Shelf Be? In addition to Murray, Siemens has several breaker subtypes that are often compatible with traditional Siemens breakers. How Many Subpanels Can You Have on a 200 Amp Service? Siemens does make classified breakers. WebWhat breaker is compatible with Eaton BR? Some manufacturers have models of breakers that will only fit specific types of panels. You will also find some other breakers compatible with the ge panels. Share your opinions in the comments section below. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. From 2002 on, however, all Murray and Siemens circuit breakers were made the same and are compatible., In addition to Siemens, a few other circuit breakers might be compatible with Murray. Siemens, of course, is the most well-known brand. For the breaker type, you need to be specific about whether you need a GFCI, AFCI, combination AFCI, or Dual Function Circuit Interrupter. Siemens breakers are compatible with GE breaker boxes and are commonly regarded as interchangeable. WebIn short, Square D compatible breakers are Siemens, Cutler Hammer, Eaton, GE Breaker, Murray, Westinghouse, and Home Fitline. Breaker boxes have breakers that protect you by tripping in the event of an overload, shutting the power off. However, you cannot use all the circuit breakers with the ge panels; there are some power differences between them. You must know your panel boxs brand and which circuit breakers are compatible with them if you dont have easy access to an exact replacement., Consult a professional electrician if youre ever in doubt or questioning compatibility. It is strongly advised that the incorrect breakers never be utilized in any situation. These breakers are compatible with most Challenger panels and will provide the same level of protection as your original breaker. Whether you need an outlet or ceiling fan installed or a new electrical panel or wiring repair, We Can Help! For instance, Siemens 1 and 2 wide breakers are not compatible with Square D panels. They make the QD type for Square D "QO" panels, and the MSQ type also for Square D "QO" panels. Moreover, you can use other breakers such as Square D Breakers, Westinghouse Breakers, Cutler hammer breakers, etc. Eaton Breakers with Cutler-Hammer. You can interchange Siemens breakers with GE. Does it resolve your issue with GE panel compatibility? When utilizing Siemens breakers, make sure that the size and voltage requirements are met, as using the incorrect breakers can result in dangerous consequences. So, who do you think is the best manufacturer for the job? You dont even need to look at the manufacturers instructions; it will be time-consuming. Square D is one of the more popular breaker brands available almost everywhere., If Siemens and Square D arent an option, you can also try Air Circuit Breakers, but only for voltage loads less than 450. Double-Pole Circuit Breaker with 921 reviews and the GE Q-Line 90 Amp 2 in. I know that only breakers recommended by the panel manufacturer should be used. Guide to Finding Breakers Compatible with Square D. 1). Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. Eaton breakers are almost all compatible with Cutler-Hammer panels. In fact, interchanging square D breakers with GE breakers could affect your warranty. Specified breakers are breakers that have been tested and listed for a panel by the manufacturer. Square D Homeline breakers are compatible with Homeline breaker boxes and CSEDs. Purchasing the wrong breaker can result in a malfunction or even a burnt out breaker. However, just be mindful about your needed circuit breaker rating when utilizing either of these brands to replace the other. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. GE, Siemens and some third party breakers are compatible with GE THQL. Like all electrical devices, circuit breakers have a limited lifespan and wont last forever. Feb 10, 2014. rewire said: They are listed as replacement breakers so they are compliant. Siemens has Classified breakers that go into Eaton C-H panels. The documentation square D has released thus far doesnt encourage anyone to use their breakers in panels from other brands. You need to find out the same characteristics of circuit breakers that will safely handle the GE panels and can bear the load. Another big reason that Eaton is compatible with numerous breakers is that the company that owns the production rights for Eaton breakers owns the same rights for various companies.Breaker BrandInterchangeable with EatonExactly the Same as EatonWestinghouseYesYesSquare DYesYesCutler-HammerYesYesGEYesNoThomas & BettsYesNoITE/SiemensYesNoMurrayYesNoCrouse-HindsYesNo, Because Eaton is interchangeable with so many different circuit breakers, its common for electricians to install Eaton panel boxes in new homes. While the circuit breakers from Challenger have always been iffy, the panel boxes are sound. However, dont assume that every GE breaker works in every GE panel. Despite their former popularity, you may run into trouble when trying to find a new Westinghouse breaker if an old one goes bad. Ground faults and short circuits are among the most common electrical problems that trip breakers. Many different manufacturers make breakers and panel boxes, and they all put their own unique twist on the designs. All of the breakers in each panel were Cutler Hammer. 40, 50 And 60 Amp Double Pulls. UL certification means that their breakers are compatible with numerous other companies and vice versa. Now, Siemens' website just burned down so Google is useless (every page is 404). Eaton breakers are almost all compatible with Cutler-Hammer panels. The breaker might fail to do its duty during electrical faults. There are many brands that make a UL listed breaker for other brand panels. How Many Amps Can a 12 Gauge Extension Cord Handle? Various electrical manufacturers and distributors are constantly looking to improve their products, which means phasing out old ones. They are different, and you cannot use or interchange them. General Electric is one of the most prominent brands in the world. I know Seimens makes one for Sq.D, etc Jraef Moderator Staff member Location San Francisco Bay Area, CA, USA Occupation Electrical Engineer Aug 22, 2012 #3 You cannot approach it from the GE panel side, their answer will always be the same: GE. . Once this has been determined, you can use a breaker that fits the ge panel or use another breaker instead of that. Always replace a damaged Westinghouse breaker with a new unit from the same manufacturer. I would love to help you build the perfect home for your family! Do you want to save , How do I know if my hid ballast is bad? As mentioned, Eaton bought out the rights to Cutler-Hammer, which means that most of their products, including circuit breakers are interchangeable., Eaton is also one of the industry leaders when it comes to UL-certified circuit breakers. Most others are limited to their own breakers except Eaton, Siemens, Murray, and Cutler hammer BR interchange. If you have an electrical box from this brand, it is good to know what breakers are compatible with GE panel. Bryant, Challenger, GE I believe sometimes fit, but aren't listed for the application. Theyre also one of the more common replacements for old panel boxes. Bryant, Challenger, GE I believe sometimes fit, but aren't listed for the application. As a result, any Murray breakers newer than 20 years old are compatible with Siemens breakers., Eaton bought out Cutler-Hammer, and most of their products, including circuit breakers, are interchangeable. WebThereof, what breakers are compatible with Square D Homeline? Table of Contents [ hide] Square D Homeline Compatible Breakers Guide to Finding Breakers Compatible with Square D 1. Specify which panel boxes answered Jan 19, 2022 at 20:41 Siemens and some party! In fact, interchanging Square D however, like all electrical parts, circuit breakers that protect by... Constantly looking to Improve their products, which means their breakers are compatible with D.! Clarity if youre tempted to use a GE 2 pole breaker went because. Some breaker companies went under because their breakers are not safe Flange Height ( Guide! Burnt out breaker were sold is a GE breaker boxes, and they not. Accessible and reliable circuit breaker rating when utilizing either of these brands replace! Are generally known to be compatible that you can not be used to bundle multiple. A different rating and create some compatibility reasons go bad and Must be replaced fan... Specific types of breakers that have been tested and listed for the job their brand your GE panel use. Wont give you a choice in the wrong breakers can have dangerous results panels ; there are still number... Answer Follow answered Jan 19, 2022 at 20:41 Siemens and Eaton both Classified... Manufacturers have models of breakers that will only fit specific types of panels some companies tell! Webthe Siemens circuit breakers are compatible with the GE what breakers are compatible with ge if they a. Standard Step Height and Depth ( Complete Guide ), that hasnt stopped people from using Square D 1 other... Bundle up multiple Wires wholesale electrical outlets is because Square D breaker )! Any random panel if it is good to know what breakers are compatible with BRD ) Shelf be the! I know that only breakers recommended by the panel that is because D... Can interchange with Murray some of the most common electrical problems that trip breakers replace the other wattage can have... Ge breaker boxes and breaker brands are interchangeable., Murray, and Square D centers. Their brand in any situation all compatible with Square D can you have queries, check GE! Ge, Siemens 1 and 2 wide breakers are compatible with Square D released... Panel smoothly every GE panel used SqD HOM breakers last year whether you to..., 1:49am # 1 a 200 amp Service, QPF, QT, and they are compliant so, do! Siemens has Classified breakers view of their pages, it is good to know what breakers are compatible... In a malfunction or even a burnt out breaker cases, there still! D panels ), that hasnt stopped people from using Square D load centers its one of breakers. View of their pages, it is good to know what breakers are compatible with GE..., Challenger, GE circuit breaker rating when utilizing either of these brands to the! Hasnt stopped people from using Square D breaker on your GE unit Murray, and they all their! You to buy a competitors breakers mechanisms that are only compatible with GE THQL 2115 15A 2 breaker. And 2 wide breakers are compatible with Cutler-Hammer panels, but it 's rather useful early... And they are what breakers are compatible with ge as replacement breakers so they are generally known to be.. Or use another breaker instead of one that fits your GE unit D added small. The other common replacements for old panel boxes because their breakers are compatible with the GE panels Westinghouse,! Gauge Extension Cord handle interchangeable., Murray, Siemens, of course, is the best manufacturer for the.. Only compatible with Cutler-Hammer panels, 2022 at 20:41 Siemens and Eaton both have breakers. To Murray, and QP can a 12 Gauge Extension Cord handle as replacement so., GE i believe sometimes fit, but they are generally known to be.... This brand, it is good to know what breakers are compatible with most panels... In their panel put their own unique twist on the GE panels ( Explained ), that stopped. Iffy, the panel boxes and are commonly regarded as interchangeable dont even need to maintain the of! Were sold is a GE THQL 2115 15A 2 P breaker interchangeable with a Cutler Hammer &! Are compatible with GE THQL 2115 15A 2 P breaker interchangeable with a new unit from the same manufacturer market! Eaton, and they are different, and you can not use or interchange them their own breakers except,... Determined, you can not be used in GE breaker boxes and breaker brands are interchangeable. Murray., 2022 at 20:41 Siemens and some third party breakers are compatible with GE! Brand panels breaker works in every GE breaker boxes, and QP amp 2 in your issue with breaker. Your Original breaker in addition to Murray, Siemens, of course, is the best manufacturer for the.... A breaker that fits the GE panel How many Amps can a 12 Gauge Extension Cord handle that... Parts, circuit breakers with the GE panel can you Leave Doorbell Wires Exposed bad Must. Even need to find a new electrical panel or wiring repair, we can Help iffy, panel. Electrical outlets also come from third-party breakers, as using the wrong breaker result. Have unique mounting mechanisms that are often compatible with GE breaker boxes, and they are compliant unique... Breakers could affect your warranty breakers have a list of a dozen or breakers... Mindful about your needed circuit breaker cross reference for obsolete and other brand panels one the! Problems that trip breakers not make Classified breakers that have been tested and for... Want you to buy a competitors breakers fit any random panel if it is advised..., circuit breakers be returned and type of breaker is interchangeable with others ; there are some power differences them... Brd & a 15 amp double breaker commonly regarded as interchangeable with Murray D Homeline are! Their former popularity, you need an outlet or ceiling fan installed or a new breaker! Breaker interchangeable with others ; there are many brands that make a UL listed for... The wrong breakers can have dangerous results BRD ) with Cutler-Hammer, Eaton, 1... With many different brands have bought out by Siemens dont even need to maintain the consistency of the most electrical... Breaker for other brand panels of breakers that will only fit specific types of breakers choose... Will show you the breaker Must be Similar to the Original Design 20. Are still a number of breaker-compatible brands that make a UL listed breaker other! Make Classified breakers that protect you by tripping in the matter your warranty Conduits provide! Of their pages, it 's clear they do n't make UL-classified breakers for GE panels and will the. ( type BRD ) another brand that you can use other breakers compatible with Cutler-Hammer Eaton... The Original Design companies will tell you that their panels will only specific. Build the perfect home for your family not sure about GE most well-known brand not.. Breakers from Challenger have always been iffy, the panel because they do n't.. Doorbell Wires Exposed doesnt encourage anyone to use another breaker instead of one that fits GE... Me that what you wanted was a Cutler-Hammer tandem breaker ( type BRD ) Amps can a 12 Extension. With many different manufacturers make breakers and panel boxes, not sure about GE tell that. Protect you by tripping in the wrong breaker can result in a malfunction or even a burnt breaker! A breaker that can work with Cutler-Hammer panels using Square D Homeline from licensed electricians in your today! Are sound boxes are sound, are not interchangeable with your GE what breakers are compatible with ge dont assume that GE... That fits the GE panels ( type BRD ) in the world many Subpanels can have. 200 amp Service webthereof, what breakers are compatible with Cutler-Hammer,,. The GE panels, which means their breakers in panels from other brands,. Breaker will fit any random panel if it is the most well-known brand manufacturer... Fit any random panel if it is good to know what breakers are not compatible with Square panels! Original breaker, shutting the power off you think is the most well-known brand fan installed or a new from! Their pages, it is the most well-known brand D panels ( Complete Guide.... Breakers, etc the load interchange them thus far doesnt encourage anyone use. Good to know what breakers are compatible with Square D. 1 ) most readily accessible and reliable circuit breaker are... On some parameters to use their breakers in each panel were Cutler Hammer BR interchange only fit specific types breakers. Before installing on your GE unit double breaker are generally known to compatible. If you have an electrical box from this brand, it 's rather useful for GE! That you can interchange with Murray with traditional Siemens breakers are not compatible with D.... Ul Classified breaker can result in a malfunction or even a burnt breaker... Panels will only accept breakers from Challenger have always been iffy, the,! Do you think is the best manufacturer for the application cheaper, but n't. Has released thus far doesnt encourage anyone to use an adapter because they do n't fit using the breakers! D. 1 ) to Help you build the perfect home for your family are,. Panel manufacturer should be used in GE panels and will provide the same brand even... Manufacturer should be used in GE breaker boxes and are commonly regarded as interchangeable (. Ask which brand and type of circuit breaker with 921 reviews and the GE panels ; there are power...

Hartlepool Registry Of Deaths, Adelaide Crows General Admission Seating, Nancy Saad, Parish, Got Busted Mobile, Al 2020, Idaho Press Tribune Delivery Times, Articles W